PRI ISDN Q.931 Multiplexer
Technical Specifications
 
Orion Telecom Networks Inc. offers VCL-PRI (Primary Rate Interface) ISDN Multiplexer provides an efficient and cost-effective platform to convert 30, dial-up, analog voice circuits to a digital E1, PRI ISDN interface, as per ITU-T Q.931 recommendations.



 

 
VCL-PRI ISDN (Euro ISDN) Multiplexer may be used to connect fully digital Corporate LANs and ISP Equipment and Networks with E1, PRI ISDN interfaces to analog PSTN circuits, or analog equipment.

FXS - Q.931 FXS .pdf - FXS interface cards - connect to analog telephone sets.
 

Digital Interface 2048 Kbps
Number of E1 Interfaces 1
Conformity (Electrical) G.703
Frame Structure As per ITU-T (CCITT) G.704
Signaling PRI ISDN (Euro ISDN) signaling as per ITU-T Rec. Q.921, Q.931
PCM Sampling Rate 8000 samples / sec.
Encoding Law A law as per ITU (CCITT) G.823
Bit Rate 2048 Kbps ± 50 ppm
Code HDB3
Nominal Impedance 120 W Balanced
Peak Voltage of a mark
120
W Balanced interface
3.0 V ± 0.3 V
Peak Voltage of a space
120
W Balanced interface
0 V ± 0.3 V
Nominal Pulse Width 244 ns
Pulse Mask As per ITU (CCITT) Rec. G.703
Output Jitter < 0.05 UI (in the frequency range of 20Hz to 100 KHz
Permissible Attenuation 6 dB at 1 MHz
Return Loss at:
51.2 KHz to 102.4 KHz
102.4 KHz to 2048KHz
2048KHz to 3072 KHz

>12dB
>18dB
>14dB
Jitter Tolerance As per ITU (CCITT) G.823
Loss and recovery of frame alignment As per clause 3 of ITU (CCITT) G.732
Loss and recovery of multi-frame alignment As per clause 5.2 of ITU (CCITT) G.732

2 Wire, Analog Interface - FXS Interface
 

Number of Interfaces per card 2
Interfaces Type FXS
Maximum Number of Channels 30
Transmission performance Fully compliant to ITU (CCITT) G.712 specifications
Line Impedance 600 W
Connector RJ11
Voice Channel Frequency 300Hz - 3400Hz
Insertion Loss -2dB Nominal (User adjustable range -2dB to -7dB
Idle Channel Noise £ -65dB
Return Loss 300Hz - 600Hz - ³ 12dB
600Hz - 3400Hz -
³ 15dB
Longitudinal Balance ³ 46dB between 300Hz to 3400Hz
Ring voltage (FXS) ³ 75 volts RMS into a load of 3 R.E.N.
Ring Frequency 20 Hz / 25 Hz (User Selectable)
Subscriber Loop Current (FXS) ³ 23 mA into a subscriber loop of 1000 Ohms
Dial Tone 400 Hz modulated by 25 Hz
Dial Tone Timeout 12 seconds
Dialing DTMF
Overload Level +3.14dBm ± 0.5dBm
Data Transmission Supports V.34 modems,
33.6Kbps (download data transmission rate)
Caller ID DTMF (provides Carrler ID to all DTMF based decoders)
 
Clock Synchronization
Synchronization Sources Internal Clock or timing derived from the E1, HDB3 link (Loop-Timed)
External Clock Input As per ITU (CCITT) Rec. G.703
Impedance of External Clock Input Port 120 W Balanced
Default Option Internal Clock
 
Power Supply
Input DC voltage -48V DC ( nominal )
Range of input -40V to -60V DC
Input Voltage Reversal Protection Provided
 
Environmental
Cooling Natural, Convection cooling
Temperature 0°C to 50°C, Ambient
Ordering Information
Core System (Common Equipment) Choice of Interface Card
Control Card FXS (Remote / Subscriber)
NMS Card  
Power Supply Card  
Connectorized Backplane & 19 inch Shelf .
Ring Generator .
 
Mechanical Specifications
Rack Mounting Standard 19 inch DIN rack
Height 3U (133.22 mm)
Depth 292 mm
Width 482 mm
Weight 8.50 Kgs.

 

Power Consumption
Power Consumption         24 Watts (Full Load)

Related Links

Others Links

Technical specifications are subject to change without notice.
All brand names and trademarks are the property of their respective owners.

 

PRI ISDN Q.931 Multiplexer - Product Brochure (PDF)
VCL-PRI ISDN

GSM Gateway / GSM Channel Banks

Echo Cancellers and Voice Quality Enhancement

Digital Access Cross Connect Switch (DACS)

Groomers (Hi-Z Non-Instrusive Monitoring)

STM SDH Multiplexer
Multiplexers
Optical Transmission
E1, T1, E3, DS3, Ethernet Converters
APS (1+1) Automatic
Protection Switch
::   Application Diagram  ::
 
Home    |   What's New   |   About Us   |   Contact Us   |   Products   |    Press   |   E-mail