VCL-3030, -101 to -104 Protocol Converter
Orion Telecom Offers Power Utility Solutions Oil & Gas Networks Solutions Railway & Metro Rail Solutions PTP IEEE-1588v2 GPS Primary Reference Clock Packet Optical Transport Multiplexers Teleprotection SCADA, FOTE, OLTE Digital Cross Connects Echo Cancellers IP/Ethernet over TDM 1+1 APS (Fail-Over) Solutions Monitoring Groomer Solutions
Description
The VCL-3030, IEC 60870-5, -101 to -104 Protocol Converter is a ruggedized and robust, sub-station-hardened protocol converter which shall convert Serial -101 data to Ethernet -104 data.
The VCL-3030, meets and complies with the IEC-61850-3, EMI, EMC, Surge and Temperature specifications making it suitable for sub-station installations to provide uninterrupted service even in the most demanding and harsh environments.
VCL-3030, -101 to -104 Protocol Converter Application:
The most common application for the VCL-3030, -101 to -104 Protocol Converter is for augmenting legacy IEC 60870-5-101 RTUs that provide serial -101 data in sub-stations and SCADA data networks. By simply installing a VCL-3030, -101 to -104 Protocol Converter the existing IEC 60870-5-101 RTUs can be upgraded to Ethernet based IEC 60870-5-104 RTUs without incurring a large capex and without the tiresome task of having to rewire the RTUs that require upgradation.
Specifications:
Technical Features:
Protocol:
- Serial Data: IEC 60870-5-101
- Ethernet Data: IEC 60870-5-104
Connectors:
- Power: Terminal Block, 2-Pin Supply Connector
- IEC 60870-5-101 Interface: DB9 Connector (RS232, RS485, RS422 user configurable interfaces).
- IEC 60870-5-104 Interface: RJ45, Ethernet Connector
Chassis:
- DIN Rail Mounting
- Power Supply: Power Supply: 12V DC, 2A
- 48V DC, 110V DC and 220V DC Power Supply Options available.
Temperature:
- Operating: -20°C to +65°C
- Humidity: 95% R.H., Non-condensing
Other Regulatory Compliance:
- Meets CE requirements
- Complies with FCC Part 68 and EMC FCC Part 15
Environmental:
Operating Temperature | -20C to +60C |
Maximum Operating Humidity | 95% R.H., Non-Condensing |
Maximum Operating Altitude | Up to 3,000 meters above sea Level |
Operation | Complies with ETS 300 019 Class 3.2 |
Storage Temperature | -40C to +70C |
Storage | Complies with ETS 300 019 Class 1.2 |
Maximum Storage Humidity | 98% R.H., Non-Condensing |
Maximum Storage Altitude | Up to 3,000 meters above sea Level |
Transportation | Complies with ETS 300 019 Class 2.3 |
Compliance / Regulatory:
- Meets CE requirements
- Complies to IEEE and IEC standards
- Complies with FCC Part 68 and EMC FCC Part 15 and CISPR 22 Class B
- Operation ETS 300 019 Class 3.2
- Operation ETS 300 019 Class 3.2
- Transportation ETS 300 019 Class 2.3