Orion Telecom Offers Power Utility Solutions Oil & Gas Networks Solutions Railway & Metro Rail Solutions PTP IEEE-1588v2 GPS Primary Reference Clock Packet Optical Transport Multiplexers Teleprotection SCADA, FOTE, OLTE Digital Cross Connects Echo Cancellers IP/Ethernet over TDM 1+1 APS (Fail-Over) Solutions Monitoring Groomer Solutions
VCL-1400, OC-3/12/48/192 SONET Multiplexer
Product Overview
The VCL-1400, OC-3/12/48/192 SONET Multiplexer with MPLS-TP is a compact POTP platform which is targeted for deployment in the edge and access part of a transport network. It can be configured both as a TDM MSPP as well as a Packet Switch. It supports both TDM and Ethernet as Line Interfaces. It offers full redundancy and comes with an expansion chassis for deployment in high drop locations and can be used in point-to-point, linear, ring, T, and mesh networks.
Features and Highlights
- POTP Evolution: SONET, OTN & Ethernet Based line Interfaces
- High Capacity Micro POTP: 1U to 4U
- Packet Switching: 60G Packet Fabric
- MPLS-TP : Traffic Engineered Pseudowires
- 50ms Protection on packet: ELPS, ERPS
- SFP based SONET and GigE ports, suitable for MM and SM fibre.
- Provides Fully diagnostic feature for each and every tributary including SFP
- Packet Synchronization: SyncE, 1588v2
- Circuit Emulation: TDM over Packet
- Recent and historic performance monitoring for each object (SONET, PDH, Ethernet, VCG and SFP Transceiver
- TDM Switching: High capacity 60G LO Fabric for efficient transport of SONET & PDH
- Supports VT1.5, VT2, STS-1 and STS-3c granularity
- User programmable ALS option
- Completion of the OS- layers, RS, MS and STS-3c
- Removing and inserting information communications SOH
- Synchronization system based on SCM (Ethernet Synchronization Message Channel)
- Front panel LED indication and connection for all tributaries
- Provides high-density tributary card (63xT1, 6xT3/DS3, 8xOC-3). Each interface is individually configurable
- Supports Synchronization Status Messaging (SSM) as per ITU-T G.813 standards.
POTP Evolution:
- VCL-1400 can seamlessly transition from 100% TDM to 100% Packet Box. It can be deployed as a TDM MSPP in SONET networks and can transport data traffic using GFP and LCAS.
- On the other hand it can be configured as a Packet Switch and deployed in Ethernet based networks. It can offer TDM services on these networks through circuit emulation.
- VCL-1400 can be deployed at gateway locations between TDM & Packet Networks and can help a network operators transition their services slowly from TDM based to packet based.
Ideal Environment
VCL-1400 can be used in the edge and the access part of the optical networks. It can be deployed as BTS or NodeB transport element in mobile networks and to build access and aggregation rings up to 10Gbps capacity.
VCL-1400 3-slot chassis can be deployed for enterprise services as a CPE or an access box. As a CPE it can provide GigE interfaces to customers, and offer L2 VPNs with QoS.
It can be used to extend L3 VPN services from a service router at central location to customer premises.With support for GigE client ports and multicast, it provides sufficient bandwidth to the DSLAM and for Video distribution.
Flexibility:
Every operator and it's network has it's own needs and requirements. VCL-1400 with it's modular architecture provides one platform which can fit into a variety of needs. This also enables a pay as you grow model. Base chassis variants of 1U (3 slot) and 2U (7 slot) along with an expansion chassis are available. A variety of line cards for both TDM and Packet help the operator arrive at the most optimal configuration for a particular requirement.
MPLS-TP:
Label Switched Paths with MPLS-TP is becoming an important requirement for scaling the network for millions of subscribers and thousands of Services today. VCL-1400 provides MPLS-TP based pseudowires for traffic enginered traffic flows on trunks, which leads to better control over the packet traffic resulting in a more optimized network. This is key to lowering capex in today's cost competitive environments. MPLS-TP is also an enabler for path level protection and restoration on the network.
VCL-1400 also supports end-toend sub-50ms path level protection by supporting ITU-T G.8031 standard on MPLS-TP tunnels.
Advanced Ethernet Features:
VCL-1400 has best in class packet switching capabilities, in line with today's requirements. Ingress rate limiting ensures that every packet entering the network is within the SLA bounds agreed with the customer. This prevents one customer from congesting/choking the packet network. Each packet is classified, so that the appropriate network policies (like prioritization and scheduling) can be applied to each kind of traffic. Options for 8 CoS queues and scheduling algorithms ensure that there are sufficient options available to the network administrator to manage the data traffic efficiently. ERPS (Ethernet Ring Protection Switching) standardized by G.8032 provides 50ms protected packet rings for greater resiliency. Multiple ringlets can be configured, and multiple ring topologies of packet networks are supported.
Packet Synchronization:
VCL-1400 also support SyncE and 1588v2 for distribution of Synchronization information over pure packet networks. This is critical for deployment in mobile networks especially for LTE, where voice is packetized but synchronization is critical for cell handoff and for ensuring jitter-free voice calls.
Circuit Emulation:
As networks move from TDM towards packet, a few TDM circuits are expected to be required for a long time due to legacy reasons. It's not cost effective to maintain an entire TDM network for this small amount of traffic. VCL-1400 supports SAToP and CESoPSN for carrying this TDM traffic over a pure packet infrastructure.
Technical Specifications
Switching Fabric
- TDM Fabric : 2.5G, 5G, 10G, 20G and 60G
- Fully Lower Order
- Packet Fabric: 60G
Aggregate Interfaces
- OC-3, OC-12, OC-48, OC-192
- 1GigE, (SFP based optical / 10 / 100 / 1000Base-T Electrical), 10GigE
Tributary Interfaces
- T1/DS1, T3/DS3
- FE/GigE (L1 & L2)
- OC-3/OC-12/OC-48
Ethernet Switching
- VLAN Switching (IEEE 802.1Q)
- Provider Bridges ( 802.1ad)
- Port Mirroring
- Ingress Rate Limiting at 64kbps granularity
- Programmable Committed and Peak Rates
- Programmable Committed and Peak Burst sizes
- Egress rate shaping on all ports
- Optical Ethernet connection: 1000Base-LX/SX and 100Base-FX (Optional)
- WAN Protocols: PPP, MLPPP
- Multi Protocol Label Switching - Transport Profile (MPLS-TP), Spanning Tree Protocol (STP) and Link Layer Discovery Protocol (LLDP)
- 8 classes of service as per IEEE 802.1p
- 2 Rate, 3 color marking
- Circuit Emulation (SATOP & CESoPSN)
Connection Oriented Ethernet
- MPLS-TP
Network Protection
- Ethernet Linear Protection Scheme as per ITU-T G.8031
- Ethernet Ring Protection Scheme as per ITU-T G.8032
- LCAS protection for Ethernet
- SNCP, 1+1 MSP for TDM Interfaces
Other Features
- T1/DS1 Tributary Retiming
- In-band channel control
Equipment Protection
- Power Supply Redundancy
- XC (cross-connect) and Aggregate Card Redundancy
- T1 tributary card redundancy
Ethernet over SONET Features
- VCAT as per ITU-T G.707
- GFP F mapping according to ITU-T G.7041
- LCAS as per ITU-T G.7042
- 64ms differential delay
- Graceful degradation in Signal Fail/ Signal Degrade
Operations & Troubleshooting
- Performance Monitoring as per G.826 and G.784
- Remote Software Download
- User configurable for Local / Remote loop
- CFM as per 802.1ag
- Performance statistics for Ethernet & VCGs
Management
- Network Management System (NMS)
- Northbound SNMPv2 interface
- End-to-end management across Valiant POTP family
- Full Remote Management Capability over TCP/IP network
- Web based Local / Remote management
- V.24/V.28 modem interface (for remote Management)
Synchronization
- SyncE, 1588 v2
- OCn, T1
- 2Mbps BITS Clock
- 2MHz TTL Clock
- Holdover, Internal
Environmental
- Operation
- Operating Temperature: 0ºC to 50ºC.
- Relative Humidity: 10% to 90%, Non-condensing.
- ETSI/EN 300386
- EN 55022 Class A
- FCC Part 15 Class A
- Storage and transport
- Temperature range: - 25°C to 70°C
- Humidity: max. 95% (non-condensing)